Yamari Vietnam Didtributor: Work Office: No 9, 651/82/3 Minh Khai street- Hai Ba Trung Dist. Hanoi Vietnam Add: No.08, Group 20, Phuc Loi Ward, Long Bien District, Ha Noi, Vietnam Tel: 0989.649.965 - Fax: +8424 36370053 Email: sales@yamari.com.vn
|
|
|
|
|
|
|
|
|
We have developed a SPRT ( BB 660/25.5 BB(S) 962/2.5 ), which provides superior stability by employing a sensing element with a single coil structure. Many experienced professionals in temperature measurement, such as those at Japanese National Laboratory and in other organizations holding JCSS accreditation, have adopted the Yamari’s SPRTs for use within their temperature laboratories.
|
|
|
Because of its construction, thin-film platinum resistance elements exhibit excellent long-term stability, interchangeability, high accuracy and high resistance to vibration. They are suited for a wide range of applications such as automobile, home electric appliances, air conditioning, energy management, medical instruments, industrial equipment, and etc.
|
Nominal Resistance(Ω) | Class | Operating Temp.(℃) |
---|
100 | A | -70 - +300 |
Nominal Dimensions (mm) | Lead Wire (mm) |
---|
Length | Width | Thickness | Length | Dia. | Material | 1.6 | 1.2 | 0.8 | 7 | 0.2 | Pt clad Ni |
|
|
|
RESIMIC has a monolithic structure comprising of platinum resistance element and MI cable (MgO compacted, metal sheathed lead wires). This RTD has very quick response, longer service life and high accuracy under critical conditions.
|
|
|
Type | PT100, JPT100 |
---|
Sheath O.D. (mm) | 3.2, 4.8, 6.4, 8.0 |
---|
Lead Connection | 2-wires, 3-wires, 4-wires |
---|
Number. of Element | 1(single), 2(double) |
---|
Rated Current | 1mA, 2mA, 5mA(only for JPT100) |
---|
Class | JIS Class A, JIS Class B |
---|
Code | Operating Temperature Range |
---|
LL | | ML | | MH | | HL | | HH | |
| *The above operating temperature range is our internal arrangement in production. |
Standard Models of RESIMIC (Model: RM)
RMB: Flexible Lead Type
RMN: Screwed-in Plain Nipple Type
RMES(L): Metal Connector Type
RMNF: Flange (Ferrule) Type
RMH: Terminal Head Type
RMP: Wall-hanging Type (for room temp.)
Mineral insulated RTD - RMA - Yamari Vietnam Temperature senssor
- RMB - Yamari Vietnam Temperature senssor
- RMBYS - Yamari Vietnam Temperature senssor
- RMH - Yamari Vietnam Temperature senssor
- RMNF - Yamari Vietnam Temperature senssor
- RMN - Yamari Vietnam Temperature senssor
- RMUN - Yamari Vietnam Temperature senssor
- RMNB - Yamari Vietnam Temperature senssor
- RMUNB -Yamari Vietnam Temperature senssor
- RMNS -Yamari Vietnam Temperature senssor
- RMUNS - Yamari Vietnam Temperature senssor
- RMNBS - Yamari Vietnam Temperature senssor
- RMUNBS -Yamari Vietnam Temperature senssor
- RMP - Yamari Vietnam Temperature senssor
- RMPB -Yamari Vietnam Temperature senssor
- RMPF - Yamari Vietnam Temperature senssor
|
|
|
|
|
|
This is the most typical resistance temperature detector comprising of metal protection tube in which the mica type RTD element is embedded with ceramic insulators and lead wires. There are two types, standard type and vibration-proof type. It has high stability and reproducibility because of its simple construction. |
Type | PT100, JPT100 |
---|
Lead Connection | 2-wires, 3-wires, 4-wires |
---|
Number of Element | 1(single), 2(double) |
---|
Rated Current | 1mA, 2 mA, 5mA(only for JPT100) |
---|
Class | JIS Class A, JIS Class B |
---|
Code | Operating Temperature Range |
---|
L | | M | | H | |
*The above operating temperature range is our internal arrangement in production.
RE12: Metal Protection Tube Type
RE13: Metal Protection Tube Typeb (Screwed)
RE14: Metal Protection Tube Type (Flanged)
|
|
|
Platinum resistance thermometers utilizing the phenomenon that the electrical resistance of any metallic conductor varies according to its temperature are widely used in industries for the measurement of temperature in the range from cryogenic to high temperature. With the best staff and advanced technologies, we manufacture a wide variety of quality products for use in general industry and explosive and hazardous areas.
|
|